Customization: | Available |
---|---|
Type: | CATV Equipment |
Function: | Signal Transmitting Device |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | Unit | Technical Parameters | |||||
Forward Path | |||||||
Frequency range | MHz | 47/54/85-862/1003 | |||||
Rated gain | dB | 30 | 34 | 36 | 38 | 40 | |
Minimum full gain | dB | ≥30 | ≥34 | ≥36 | ≥38 | ≥40 | |
Rated input level | dBμV | 72 | |||||
Rated output level | dBμV | 108 | |||||
Flatness in band | dB | ±0.75 | |||||
Noise figure | dB | ≤10 | |||||
Return loss | dB | ≥16 | |||||
Attenuation | dB | 1-18 (Fixed insert,1dB stepping, specified by the user) | |||||
Equilibrium | dB | 1-15 (Fixed insert,1dB stepping, specified by the user) | |||||
C/CTB | dB | 70 | Test condition: 84 channels signal, output level: 85MHz/550MHz/860MHz. 99dBuV/105dBuV/108 dBuV |
||||
C/CSO | dB | 68 | |||||
Group delay | ns | ≤10 (112.25 MHz/116.68 MHz) | |||||
AC hum modulation | % | < 2% | |||||
Gain stability | dB | -1.0 ~ +1.0 |
Return Path | |||
Frequency range | MHz | 5 ~ 30/42/65 | |
Rated gain | dB | ≥20 | |
Minimum full gain | dB | ≥22 | |
Maximum output level | dBμV | ≥ 110 | |
Flatness in band | dB | ±0.75 | |
Noise figure | dB | ≤ 8 | |
Return loss | dB | ≥ 16 | |
Carrier to second-order inter-modulation ratio | dB | ≥ 52 | Test Condition: Output level 110dBuV, test points: f1=10MHz, f2=60MHz, f3=f2-f1=50MHz |
Group delay | ns | ≤ 20 (57MHz/59MHz) | |
AC hum modulation | % | < 2% | |
General Performance | |||
Characteristic impedance | Ω | 75 | |
Test port | dB | -20±1 | |
Power supply voltage | V | A:AC(135 ~ 250)V;B:AC(45 ~ 90)V | |
Impulse withstand voltage(10/700μs) | kV | > 5 | |
Power consumption | W | 35 | |
Dimension | mm | 295(L)x 210(W)x150(H) |